UltraECM3 HSPI Installation
Downloading and Installing the HomeSeer Plug-in
1. From your HomeSeer web page, select PLUG-INS > Manage.
2. Click the + icon next to Additional Interfaces to expand the list of available HomSeer3 plug-ins.
3. Click the + icon next to the “Hardware Interface Plug-Ins” category, then click the checkbox next
to the UltraECM3 plug-in package to mark the plug-in for installation.
4. Under “Pending Updates/Installs”, click the Download and Install button.
5. Once the installer finishes, find the UltraECM3 plug-in under Installed Plug-Ins, then enable it.
UltraECM3 HSPI Setup
Before you begin to configure the UltraECM3 plug-in, you’ll need to make sure you test connectivity to
the Brultech ECM devices. Refer to the Brultech documentation for additional information.
Initial Setup Checklist
1. Brultech ECM-1240 Installation – Refer to the Brultech ECM-1240 Install Guide and User Manual
on how to install and configure the energy consumption monitors.
2. Brultech GreenEye Monitor (GEM) Installation - Refer to the Brultech GEM Install Guide and
User Manual on how to install and configure the energy consumption monitors.
Under Network > Remote Host, enter the IP address of your HomeSeer system and port 8000,
then click Save. This is server mode, so you'll want to use client mode within the UltraECM3
plug-in (e.g. 0.0.0.0:8000). You should also select BIN48-NET (5) for the packet format.
3. Start HomeSeer and ignore any UltraECM3 errors indicating the ECM interface is disabled.
Select UltraECM3 > Devices to add each Brultech device connected to your HomeSeer system.
a. Device Serial: Enter the Brultech serial number (or any unique number of you don’t
know the serial number). The serial number will be populated once the plug-in makes a
connection to the Brultech device.
b. Device Name: Enter the Brultech device alias (e.g. Basement Main Panel).
c. Device Type: Select from one of the supported Brultech device types.
d. Connection Type: Select the type of connection used to connect HomeSeer to the
Brultech ECM device.
e. Connection Address: If you are using a Serial Connection, enter COM:N where N is the
serial port number. If you are using an Ethernet Connection: If the Brultech device is
using server mode, enter 0.0.0.0:8000 where 8000 is the TCP port defined within the
GEM. If the Brultech device is using client mode, then enter n.n.n.n:ppp where n.n.n.n
Kommentare zu diesen Handbüchern