GreenEye Monitor
© Brultech Research Inc. 11 www.brultech.com
COMMUNICATION SETUP (WIFI/ETHERNET MODULE)
Figure 13
Refer to Figure 13:
1. Log into your WiFI/Ethernet modules setup page.
2. Click on the Application Setting menu option.
3. Enter the following settings:
Set the Mode to Client.
Set the Protocol to TCP
Set the Port to “80”
Set the Server Address to “api.smartenergygroups.com”
Click the Apply button.
4. Click on the Device Management menu option.
5. Click the Restart button.
The Restart button causes the settings to take effect and re-boots the communication module.
Once the GEM starts sending to SmartEnergyGroups.com, you will no longer be able to access the GEM
setup page unless you set the WiFi/Ethernet module back to Server mode and change the port number
to something other than 80 (Port 8000 is recommended).